LabTek is a renowned manufacturer, supplier, solution provider and exporter of Concrete testing machines, building and civil engineering laboratory equipment and accessories. We are supplying the equipment to quality testing laboratories civil builders, civil contractors, Engineering colleges, Universities and Polytechnics. We manufacture the best quality Automatic Compression testing machines, Semi Automatic or Digital Compression testing machines, Electrical cum Hand Compression testing machines, Hand operated or Manual Compression testing machines or Cube Testing Machines or Compressive strength testing machines as per the international standards and specifications. Sand Absorption Cone And Tamper.

Sand Absorption Cone And Tamper

Sand Absorption Cone And Tamper

Make: LabTek

Model: SL-2060

Origin: India

Standards: ASTM C 128 AASHTO-T-84

Specification:
The equipment comprises of a conical metal mould 1.5 inch dia at to top, 3.5 inch dia at base and 27/8 inch in height. A metal tamping rod weighting 12 ounces and having a flat circular tamping faces 1 inch in dia meter.

 

Sand Absorption Cone And Tamper

Sand Absorption Cone And Tamper

Relative Density (Specific Gravity) and Absorption of Fine Aggregate1

This standard is issued under the fixed designation C128; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (ε) indicates an editorial change since the last revision or reapproval.

  1. Scope

1.1  This test method covers the determination of relative density (specific gravity) and the absorption of fine aggregates. The relative density (specific gravity), a dimensionless quality, is expressed as oven-dry (OD), saturated-surface-dry (SSD), or as apparent relative density (specific gravity). The OD relative density is determined after drying the aggregate. The SSD relative density and absorption are determined after soaking the aggregate in water for a prescribed duration.

1.2  This test method is not intended to be used for lightweight aggregates that comply with Specification C332 Group I aggregates.

1.3  The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4  The text of this test method references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this test method.

1.5  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.