The heat sink is realized by means of a water-cooling system. An elevated tank ensures a constant cooling water flow rate. A temperature jump can be generated by appropriate regulation of the cooling water flow. A PC can be used to display the transient temperature distribution in the sample over time and place.
The temperatures of the sample, heating and cooling water, as well as the electrical heating power and the cooling water flow rate are displayed digitally on the switch cabinet and can be transmitted simultaneously via USB directly to a PC where they can be analyzed using the software included. The thermal conductivity λ can be calculated from the measured data.
FEATURES
- Steady heat conduction
- Transient heat conduction
- Temperature/time profiles
- Calculate thermal conductivity λof different metals
- Steady and transient heat conduction in metals
- 12 temperature measurement points in every sample
- Regulated temperature of the heat source
SPECIFICATION
Output: 800W
Temperature: 20…85°C
3x 450mm (copper, aluminum, brass)
2x 300mm (steel, stainless steel)
- Heating tank: ca. 2L
Cooling tank: ca. 0,5L
Elevated tank: ca. 6L - Temperature sensors
12x thermocouple type K, along the sample
2x Pt100, in the cooling water
1x Pt100, in the heating water
- Measuring ranges
temperature: 14x 0…100°C
Power: 0…1000W
Flow rate: 0,1…2,5L/min
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase; 120V, 60Hz, 1 phase
DIMENSIONS AND WEIGHT
- LxWxH (approx.): 1200x800x1600mm
- Weight (approx.): 120kg