The experimental plant is built in accordance with statutory safety regulations and includes the mandatory safety facilities. The steam generator is type tested and does not require specific permissions.
The plant can optionally be operated with the cooling tower.
FEATURES
- steam power plant and its components
- start-up, operation and shut down of a steam power plant
- closed steam-water circuit with feed water treatment
- among others, determining:
- boiler efficiency
- mechanical/thermal efficiency of the turbine
- condenser efficiency
- specific fuel consumption of the plant
SPECIFICATION
Steam generator
- steam output: 200kg/h at 11bar
- fuel consumption: 12L/h
- heat-up time: 8min
- pressure: 13bar
Super heater
Single-stage axial turbine with Curtis wheel and hydraulic speed regulator
- power: max. 1,5kW at 3000min-1
Water-cooled condenser
- cooling capacity: 98kW
- transfer surface: 2,5m2
Measuring ranges
- temperature: 9x 0…400°C, 2x 0…100°C
- flow rate: 0…167L/min (cooling water)
- pressure: 3x 0…16bar, 1x ±1bar
- torque: 0…20Nm
- speed: 0…4000min-1
400V, 50Hz, 3 phases
400V, 60Hz, 3 phases, 230V, 60Hz, 3 phases
DIMENSIONS AND WEIGHT
- L x W x H: 3500x 2500 x 2250 mm
- Weight (approx.): 2250 KG